At the ASHRAE Winter Conference in Chicago, IL, there was much discussion around the topic of efficient data center cooling. One of the contributing factors to the increased discussion was ASHRAE’s decision to raise the recommended supply air temperature for data centers from 77 degrees Fahrenheit to 80.6 degrees Fahrenheit. The widening of the range is consistent […]
The fully integrated packaged central plant by Chil-Pak® is an excellent solution for data center cooling. Chil-Pak® is a manufacturer of integrated packaged plants that provides complete chilled water solutions at the lowest possible cost to building owners in just a few months. The Chil-Pak® Central Plant SolutionTM reduces engineering design time, reduces the cost of field […]
The IDU™ by United Metal Products® is an excellent solution for energy efficient data center cooling. The IDU™ can help mission critical facility owners and operators achieve upwards of fifty percent power savings over traditional cooling systems without the use of any compressors. The IDU™ uses environmentally friendly cooling technology and is completely free of harmful CFC’s […]
With over 30 years of experience providing energy efficient cooling solutions, United Metal is the natural choice when it comes to providing green cooling solutions for data centers. The solution based cooling designs that United Metal Products offers provides mission critical facilities with a range of choices to meet their specific needs. “United Metal Products is offering […]
As the accepted temperature ranges in data centers have increased, it has provided many opportunities for financial savings and energy efficiency. United Metal Products has developed a range of compressor free cooling systems to help data center facilities achieve maximum energy savings without sacrificing reliability. In order to assist owners with multiple sites, United Metal Products offers […]
United Metal Products has developed an energy efficient cooling technology that provides chilled water temperatures below wet-bulb without the use of any compressors. This innovative technology can help data centers save hundreds of thousands of dollars by eliminating the need for mechanical cooling. To learn more about how you can apply the energy efficient technology of the […]
A Fortune 10 financial company has chosen United Metal Products Indirect-Direct Solution for their Data Center Cooling infrastructure. The client was in discussion with several other manufacturer’s but found United Metal Products mission critical team to be the most knowledgeable and helpful in designing the needed system. United Metal worked with the Fortune 10 company to take […]
One of the most important challenges to address in the mission critical space is the airflow distribution in the white space. The following are an adapted version of the best practices recommended by ASHRAE Technical Committee 9.9 in the mission critical space when it comes to airflow distribution: A proper analysis of the facility should be done […]
As more and more data centers, labs, and telecommunication facilities implement energy efficient cooling solutions such as evaporative cooling it is important to address the fan energy that is being used in the distribution equipment. There are several best practices recommended by ASHRAE for energy optimization. Below are eight of ASHRAE’s TC 9.9 recommendations for improving fan […]
Two weeks ago at the AFCOM National Conference in Las Vegas, United Metal Products announced a super efficient cooling solution for data centers and other mission critical facilities. The solution is known as the DC-ERATM. This energy saving cooling system has been specifically designed for the higher allowable cold aisle temperatures being applied in today’s Data Centers. […]